DC/DC Converter
THD 10N Series, 10 Watt
•
•
Wide 2:1 input voltage range
•
•
High efficiency up to 89%
•
•
•
I/O isolation 1'500 VDC
Internal EMI-filter meets EN 55022,
Class A without external components
Operating temperature range
–40°C to +85°C
UL 62368-1 IEC 62368-1
The THD 10N series is a range of isolated high performance 10W DC/DC converters in a low profile DIL-24 package with standard industry pin-out. Other
features of this product are built-in overvoltage protection and internal EMI-filter to meet EN 55022, class A. Full SMD-design with exclusive use of ceramic
capacitors guarantees a high reliability and long product lifetime. Typical applications for these converters are industrial electronics, instrumentation, data
communication systems and battery operated equipment with limited space
available on the PCB.
Overload protection
3-year product warranty
Models
Order Code
Input Voltage
Range
THD 10-1210N
THD 10-1211N
THD 10-1212N
THD 10-1213N
THD 10-1222N
THD 10-1223N
THD 10-2410N
THD 10-2411N
THD 10-2412N
THD 10-2413N
THD 10-2422N
THD 10-2423N
THD 10-4810N
THD 10-4811N
THD 10-4812N
THD 10-4813N
THD 10-4822N
THD 10-4823N
www.tracopower.com
9 - 18 VDC
(12 VDC nom.)
18 - 36 VDC
(24 VDC nom.)
36 - 75 VDC
(48 VDC nom.)
Output 1
Output 2
Vnom
Imax
3.3 VDC
5.1 VDC
12 VDC
15 VDC
+12 VDC
+15 VDC
3.3 VDC
5.1 VDC
12 VDC
15 VDC
+12 VDC
+15 VDC
3.3 VDC
5.1 VDC
12 VDC
15 VDC
+12 VDC
+15 VDC
2'700 mA
2'000 mA
833 mA
666 mA
416 mA
333 mA
2'700 mA
2'000 mA
833 mA
666 mA
416 mA
333 mA
2'700 mA
2'000 mA
833 mA
666 mA
416 mA
333 mA
March 10, 2022
Vnom
Efficiency
Imax
–12 VDC
–15 VDC
416 mA
333 mA
–12 VDC
–15 VDC
416 mA
333 mA
–12 VDC
–15 VDC
416 mA
333 mA
typ.
86 %
85 %
88 %
89 %
88 %
89 %
86 %
85 %
89 %
89 %
88 %
89 %
86 %
85 %
87 %
88 %
87 %
88 %
Page 1 / 4
THD 10N Series, 10 Watt
Input Specifications
Input Current
- At no load
12 Vin models:
24 Vin models:
48 Vin models:
12 Vin models:
24 Vin models:
48 Vin models:
12 Vin models:
24 Vin models:
48 Vin models:
12 Vin models:
24 Vin models:
48 Vin models:
- At full load
Surge Voltage
Under Voltage Lockout
Recommended Input Fuse
Input Filter
20 mA typ.
15 mA typ.
10 mA typ.
940 mA typ.
470 mA typ.
240 mA typ.
25 VDC max. (1 s max.)
50 VDC max. (1 s max.)
100 VDC max. (1 s max.)
8.5 VDC max.
17 VDC max.
34 VDC max.
(The need of an external fuse has to be assessed
in the final application.)
Internal Pi-Type
Output Specifications
Voltage Set Accuracy
Regulation
- Input Variation (Vmin - Vmax)
- Load Variation (0 - 100%)
Ripple and Noise
(20 MHz Bandwidth)
- Voltage Balance
(symmetrical load)
- single output
- dual output
Capacitive Load
- single output
- dual output
±2% max.
1% max.
1% max.
1.2% max.
1.2% max. (Output 1)
1.2% max. (Output 2)
dual output models: 2% max.
single output models:
dual output models:
single output models:
dual output models:
3.3 Vout models:
5.1 Vout models:
12 Vout models:
15 Vout models:
12 / -12 Vout models:
15 / -15 Vout models:
3.3 Vout models:
5.1 Vout models:
12 Vout models:
15 Vout models:
12 / -12 Vout models:
15 / -15 Vout models:
Minimum Load
Temperature Coefficient
Short Circuit Protection
Output Current Limitation
Transient Response
- Response Deviation
- Response Time
80 mVp-p typ.
80 mVp-p typ.
100 mVp-p typ.
100 mVp-p typ.
100 / 100 mVp-p typ.
100 / 100 mVp-p typ.
1'000 µF max.
1'000 µF max.
470 µF max.
330 µF max.
220 / 220 µF max.
150 / 150 µF max.
Not required
±0.02 %/K max.
Continuous, Automatic recovery
110% min. of Iout max.
150% typ. of Iout max.
3% typ. / 5% max. (75% to 100% Load Step)
300 µs typ. / 600 µs max. (75% to 100% Load
Step)
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
March 10, 2022
Page 2 / 4
THD 10N Series, 10 Watt
Safety Specifications
Safety Standards
CSA-C22.2, No. 60950-1
EN 60950-1
EN 62368-1
IEC 60950-1
IEC 62368-1
UL 60950-1
UL 62368-1
www.tracopower.com/overview/thd10n
PD 2
- IT / Multimedia Equipment
- Certification Documents
Pollution Degree
EMC Specifications
EMI Emissions
- Conducted Emissions
- Radiated Emissions
External filter proposal:
EMS Immunity
- Electrostatic Discharge
Air:
Contact:
- RF Electromagnetic Field
- EFT (Burst) / Surge
Ext. input component:
- Conducted RF Disturbances
EN 55032 class A (internal filter)
EN 55032 class A (with external filter)
www.tracopower.com/overview/thd10n
EN 55024 (IT Equipment)
EN 61000-4-2, ±8 kV, perf. criteria A
EN 61000-4-2, ±6 kV, perf. criteria A
EN 61000-4-3, 10 V/m, perf. criteria A
EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±1 kV, perf. criteria A
220 μF, 100 V
EN 61000-4-6, 10 Vrms, perf. criteria A
General Specifications
Relative Humidity
Temperature Ranges
Power Derating
Cooling System
Remote Control
- Operating Temperature
- Case Temperature
- Storage Temperature
- High Temperature
- Voltage Controlled Remote
- Off Idle Input Current
- Remote Pin Input Current
Altitude During Operation
Switching Frequency
Insulation System
Isolation Test Voltage
Isolation Resistance
Isolation Capacitance
Reliability
Washing Process
- Input to Output, 60 s
- Input to Output, 1 s
- Input to Output, 500 VDC
- Input to Output, 100 kHz, 1 V
- Calculated MTBF
See Cleaning Guideline:
Housing Material
Base Material
Potting Material
Pin Material
Pin Foundation Plating
Pin Surface Plating
Housing Type
Mounting Type
95% max. (non condensing)
–40°C to +85°C
+105°C max.
–50°C to +125°C
2.86 %/K above 70°C
Natural convection (20 LFM)
On: 3.5 to 12 VDC or open circuit
Off: 0 to 1.2 VDC or short circuit
Refers to 'Remote' and '-Vin' Pin
10 mA max.
-0.5 to 0.5 mA
6'000 m max.
330 kHz typ. (PWM)
Functional Insulation
1'500 VDC
1'800 VDC
1'000 MΩ min.
1'000 pF typ.
1'500 pF max.
1'000'000 h (MIL-HDBK-217F, ground benign)
Allowed (hermetical product)
www.tracopower.com/info/cleaning.pdf
Metal
Non-conductive Plastic (UL 94 V-0 rated)
Silicone (UL 94 V-0 rated)
Copper Alloy (C6801)
Nickel (2 - 4 µm)
Tin (3 - 5 µm), matte
Metal Case
PCB Mount
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
March 10, 2022
Page 3 / 4
THD 10N Series, 10 Watt
Connection Type
Footprint Type
Soldering Profile
THD (Through-Hole Device)
DIP24
Wave Soldering
260°C / 10 s max.
17.3 g
www.tracopower.com/info/reach-declaration.pdf
REACH SVHC list compliant
REACH Annex XVII compliant
www.tracopower.com/info/rohs-declaration.pdf
Exemptions: 7a
(RoHS exemptions refer to the component
concentration only, not to the overall
concentration in the product (O5A rule).
The SCIP number is provided on request.)
Weight
Environmental Compliance - REACH Declaration
- RoHS Declaration
Supporting Documents
Overview Link (for additional Documents)
www.tracopower.com/overview/thd10n
Outline Dimensions
11
22
16
2.54
23
14
(0.80)
Pinout
(0.60)
9
20.3
3
15.22
2
(0.10)
1
Pin
Single
Dual
1
Remote On/Off
Remote On/Off
2
–Vin (GND)
–Vin (GND)
3
–Vin (GND)
–Vin (GND)
9
No pin
Common
–Vout
11
NC
14
+Vout
+Vout
16
–Vout
Common
22
+Vin (Vcc)
+Vin (Vcc)
23
+Vin (Vcc)
+Vin (Vcc)
10.2
(0.40)
4.1
Ø 0.5
(0.16)
NC: Not connected
(Ø 0.02)
2.54 2.54
15.24
5.08
4.5
(0.10) (0.10)
(0.60)
(0.20)
(0.18)
31.8
(1.25)
Dimensions in mm (inch)
Tolerances: x.x ±0.50 (±0.02)
Tolerances: x.xx ±0.25 (±0.01)
Pin diameter ±0.05 (0.002)
© Copyright 2022 Traco Electronic AG
Specifications can be changed without notice.
www.tracopower.com
Rev. March 10, 2022
Page 4 / 4